Validation of the thoracic impedance derived respiratory signal using multilevel analysis

The purpose of the current study was to validate the change in thoracic impedance (dZ) derived respiratory signal obtained from four spot electrodes against incidental spirometry. Additionally, a similar validation was performed for a dual respiratory belts signal to compare the relative merit of both methods. Participants were 38 healthy adult subjects (half male, half female). Cross-method comparisons were performed at three (paced) respiration frequencies in sitting, supine and standing postures. Multilevel regression was used to examine the within- and between-subjects structure of the relationship between spirometric volume and the respiratory amplitude signals obtained from either dZ or respiratory belts. Both dZ derived respiratory rate and dual belts derived respiratory rate accurately reflected the pacing frequencies. For both methods, fixed factors indicated acceptable but posture-specific regression on spirometric volume. However, random factors indicated large individual differences, which was supported by variability of gain analyses. It was concluded that both the dZ and dual belts methods can be used for measurement of respiratory rate and within-subjects, posture-specific, changes in respiratory volume. The need for frequent subject-specific and posture-specific calibration combined with relatively large measurement errors may strongly limit the usefulness of both methods to assess absolute tidal volume and minute ventilation in ambulatory designs.

Validity of the Empatica E4 Wristband to Measure Heart Rate Variability (HRV) Parameters: a Comparison to Electrocardiography (ECG)

Wearable monitoring devices are an innovative way to measure heart rate (HR) and heart rate variability (HRV), however, there is still debate about the validity of these wearables. This study aimed to validate the accuracy and predictive value of the Empatica E4 wristband against the VU University Ambulatory Monitoring System (VU-AMS) in a clinical population of traumatized adolescents in residential care. A sample of 345 recordings of both the Empatica E4 wristband and the VU-AMS was derived from a feasibility study that included fifteen participants. They wore both devices during two experimental testing and twelve intervention sessions. We used correlations, cross-correlations, Mann-Whitney tests, difference factors, Bland-Altman plots, and Limits of Agreement to evaluate differences in outcomes between devices. Significant correlations were found between Empatica E4 and VU-AMS recordings for HR, SDNN, RMSSD, and HF recordings. There was a significant difference between the devices for all parameters but HR, although effect sizes were small for SDNN, LF, and HF. For all parameters but RMSSD, testing outcomes of the two devices led to the same conclusions regarding significance. The Empatica E4 wristband provides a new opportunity to measure HRV in an unobtrusive way. Results of this study indicate the potential of the Empatica E4 as a practical and valid tool for research on HR and HRV under non-movement conditions. While more research needs to be conducted, this study could be considered as a first step to support the use of HRV recordings provided by wearables.

Stress in action wearables database: A database of noninvasive wearable monitors with systematic technical, reliability, validity, and usability information

Ambulatory wearable monitoring of human physiology is increasingly utilized in the fields of psychology, movement sciences, and medicine. With the rapid growth of available consumer- and research-oriented wearables, researchers are faced with a multitude of devices to choose from. It is unfeasible timewise for researchers to determine all relevant technical specifications, available signals, signal sampling details, and (raw) data availability, and conduct a search of studies regarding the reliability, validity, and usability of wearables. Thus, selection of wearables for a given study proves highly challenging and will often be unsystematic and uninformed. The 10-year research program Stress in Action initiated a publicly accessible database of wearable ambulatory monitoring devices. We outline the genesis and final structure of the first version of the Stress in Action Wearables Database (SiA-WD) and a summary of the characteristics of the wearables it currently contains. Furthermore, one short-term (2 days) and one long-term (3 months) scenario from the field of stress research are provided with walkthroughs of how the SiA-WD can help select the optimal wearable for a specific research project. Insights gathered include the scarceness of studies testing wearable user-friendliness, inconsistencies in reported validity statistics, and imprecise manufacturer documentation on recorded physiological data such as sampling rate (or window) of signals and parameter extraction. The SiA-WD is the first open-access database to simultaneously include physiological sampling information and technical specifications along with a systematic reliability, validity, and usability search. It will be iteratively expanded to facilitate informed and time-efficient wearable selection. For access to the database, see the following: https://osf.io/umgvp/.